دستور العمل های بهره برداری و نت کوپلینگ های (OZGUN MAKINIA (J DRUM



ASSEMBLY

Be sure coupling is clean at assembly.
Check the right assembly distance (S). Wrong assembly distance could block axial capability of coupling.
•All O-rings (4) should be covered from heat during shrink fit of shaft to hub.
•Align the coupling (1, 2, 3, 4) with laser shaft alignment equipment to prevent maximum axial and angular misalignments. Lifetime of coupling will be too short in case of usage of couplings out of specified misalignment tolerances.
• Couplings bore tolerance should be machined up to shafts tolerance to prevent much clearance what causes additional force on keyway.
•Straight surfaces (G) at two sides of the coupling should be limited after coupling assembled and bolts have been tightened.
•Type of grease used in it's intended use in accordance with the following table (at high temperatures, necessarily heavy-duty) should be selected, and qty from catalogue.

DISASSEMBLING and INSPECTION

•There are signs (MAX) at the frontal face of couplings which shows detrital of tooth. Please change your coupling immediately if the arrow is at the end of right or left sign.
•Disassembly and check gears (1, 2) and O-rings (4) and alignment at each 8.000 hours or 2 years.

OPERATION and MAINTENANCE

• Grease should be added every 90 days, but especially the usage at high-temperature places more frequent and continuous follow-up periods should be replaced. Empty grease once in a year and clear inside of the coupling with
solvent, then add new grease again as specified qty on cataloque.
• Sealing equipments should be checked every lubrication and too sclerous or warned O-rings should be changed immediately. In case of disassembly is not possible, o¬rings could be pasted endwise.


FOR HEAVY OUTY CODE BRAND
X ERAGREASE LOADMASTER 2 ERALUBE
X ERAGREASE RSE/MC-HV ERALUBE
X ERAGREASE RSE/MC-MOL Y ERALUBE
  ERAMOL Y 2 PLUS ERALUBE
  ALVANIA GREASE EP MOS SHELL
  BR2 PLUS MOLYKOTE
  UNIMOLI GL 82 KLUEBER
  ENERGREASE L21-M BP